Room Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable Fan

Product Details
Customization: Available
Timer: With Timer
Remote Control: Without Remote Control
Still deciding? Get samples of US$ 80/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Customization from Samples
The supplier provides sample based customization services
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (6)
  • Room Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable Fan
  • Room Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable Fan
  • Room Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable Fan
  • Room Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable Fan
  • Room Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable Fan
  • Room Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable Fan
Find Similar Products

Basic Info.

Model NO.
9030
Watertank Capacity
10-20L
Noise Level
Low
Mounting
Floor Standing
Application
Household, Commercial, Industrial
Transport Package
Carton
Trademark
OEM
Origin
Cixi, Ningbo
HS Code
84796000
Production Capacity
90000

Product Description

Room Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable FanRoom Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable Fan
Room Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable FanRoom Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable FanRoom Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable FanRoom Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable FanRoom Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable FanRoom Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable FanRoom Air Conditioner Air Conditioner Cooler Window Air Conditioner Portable Mini Air Conditioner Desert Cooling System Industrial Stand Fan Rechargeable Fan
Evaporative Air Cooler with heater

Voltage: 220-240V~50/60Hz/DC 12V
Rated cooling power:30W
Tank Capacity:15L
N/G Weight:7KGS/10KGS
Control Mode:Remote control 
Applying Wind distance: 4M-6M
Lithium battery specification:5000mAh(18650*6pcs)
Product dimension:375*335*770mm
Packing Dimension:420*375*790mm
504PCS/40HQ



FAQ

Q1: How does the cold air fan do not produce cold air?
The possible causes may include:The tank is short of water or the ice crystals have melted.
The fan filter screen is blocked and needs to be cleaned.
The cooling components of the fan such as the wet curtain need to be replaced.
Check the tank water level, clean the filter screen, and consider replacing the refrigeration components.

Q2: When the cooling fan is noise, how to solve it?
Noise may be caused by the following reasons:Fan blades are unbalanced or damaged.
Motor bearing wear.
The cooling fan placement is not stable.Check the fan blades and replace the motor bearings to ensure that the cooling fan is placed on a stable and flat surface.

Q3: The refrigeration effect of the cooling fan is not good, how to do it?
The following possible reasons are provided:The environmental humidity is too high, which affects the refrigeration effect.
Refrigeration components such as wet curtain aging.
The wind speed of the fan setting is too low.
Try using it when the humidity is low, replace the cooling components, or adjust the wind speed setting.

Q4: Cold fan smell out, how to solve it?.
The odor may be due to:Not clean for a long time, leading to bacterial breeding.
The water quality in the tank is poor or not replaced for a long time.
Clean the cooling fans regularly, replace the water in the water tank, and use pure water or add an appropriate amount of disinfectant.

Q5: What is the cold fan not rotating?.
The possible causes include:Power problem, power not connected or power unstable.
Motor failure.
Remote control or control panel failure.
Check the power connection and verify that the motor and control panel are properly.

Q6: What if the remote control of the cooling fan cannot be controlled?
The following possible reasons are provided:
Remote control battery is exhausted.
The signal between the remote control and the cold fan is blocked.
The remote control itself fails.
Replace the remote control battery, check for an object blocking signal, or try to operate directly on the cooling fan.

Q7: What happens if the cooling fan leaks?
The possible causes include:Water tank leakage.
Drain pipe is blocked or improperly located.
Refrigeration components such as wet curtain installation.
Check the water tank and drain pipe to ensure that the cooling components are installed correctly.

Q8: How to clean the water tank of cold fans?
The steps of cleaning the water tank include:
Disgle the power and pour the water in the water tank.
Use mild cleaner and water to clean the water tank.
Rinse it with water and reinstall it after drying.

Q9: Does the cold fan need to be maintained regularly?
Yes, in order to ensure the performance and service life of cold fans,
Suggestion: Clean the filter every two weeks.
Check the refrigeration parts every month like a wet curtain.
Maintain comprehensive maintenance every six months or a year.

Send your message to this supplier